Sanitizer Plus Series® Water Conditioners
104. POWER LOSS AND BATTERY REPLACEMENT: The AC transformer comes with a 15 foot power cord and is designed for use with the control valve; the t
11• After installation is complete, rotate bypass handles to bypass mode (see Fig.2 on page 4).• Turn on water and check for leaks.• Fully open a cold
12 PROBLEM CAUSE CORRECTION 1. No display on PC board A. No power at electric outlet A. Repair outlet or use working outlet B. Control valve po
13 7. Control valve does not regenerate automatically but does when the correct button(s) is depressed and held. For timeclock valves the buttons ar
14 12. Control valve fails to draw in regenerant A. Injector is plugged A. Remove injector and clean or replace B. Faulty regenerant piston B.
15 PROBLEM CAUSE CORRECTION 15. E2, Err – 1002, Err – 102 = Control valve motor ran too short and was unable to find the next cycle position and s
16TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION 19. Err – 1007, Err – 107, Err - 117 = MAV/ SEPS/NHBP/AUX MAV valve motor ran too short (stalle
17 REPLACEMENT PARTS:2713546FRONT COVER AND DRIVE ASSEMBLYItem No. Part No. Description Qty.1CV3540S-A Black cover 1CV3540-WS-A Gray cover 12 CV3107
186810117 97 12423511314NOTE: Not available on 1¼ " valve. REPLACEMENT PARTS:PISTON ASSEMBLYItem No. Part No. Description Qty.1CV3005
19 REPLACEMENT PARTS:BYPASS VALVE Item No. Part No. Description Qty.1 CV3151 Nut, 1” quick connect 22 CV3150 Split ring 23 CV3105 O-ring 215 24 CV3
TABLE OF CONTENTSPreinstallation Instructions for Dealers ... 3Bypass Valve ...3
20INJECTOR ASSEMBLIESItem No. Part No. Description Qty.1CV3176 Injector cap 12CV3152 O-ring 135 13CV3177-01 Injector screen 14CV3010-1Z Injector a
DRAIN LINE ASSEMBLY 3/4”Item No. Part No. Description Qty.1 CH4615 Elbow locking clip 12 CPKP10TS8-BULK Optional insert, 5/8” tube 13 CV3192 Option
22 WATER METER & METER PLUGItem No. Part No. Description Qty.1 CV3151 Nut, 1” QC 12 CV3003 Meter assembly, includes items 3 & 4 13 CV3118-01
23 REPLACEMENT PARTS:1234567810234561911BRINE TANK ASSEMBLYItem No. Part No. Description Qty.1CG2191-84 Brine tank cover, injection molded WR 1CG2180
241” PVC MALE NPT ELBOWItem No.Part No. Description Qty.CV3007 1” PVC male NPT elbow assembly 21 CV3151 Nut, 1” quick connect 22 CV3150 Split ring
251-1/4” & 1-1/2” PVC SOLVENTItem No.Part No. Description Qty.CV3007-07 1-1/4” & 1-1/2” PVC solvent assembly 21 CV3151 Nut, 1” quick connect
26 SPECIFICATIONS:1 All Sanitizer Plus water conditioners are pre-factory set at medium salting. Note: influent waters must be at least 3 GPG hardnes
27Water Conditioner Limited WarrantyCongratulations. You have purchased one of the nest water treatment systems available. In the unlikely event of a
1900 Prospect Court • Appleton, WI 54914Phone: 920-739-9401 • Fax: 920-739-9406MANUAL REGENERATIONNOTE: For softeners, if brine tank does not cont
PREINSTALLATION INSTRUCTIONS FOR DEALERS: BYPASS VALVE:3The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt
41. NORMAL OPERATION POSITION: The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Wa
5GENERAL INSTALLATION & SERVICE WARNINGSThe control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There
66. INLET/OUTLET PLUMBING: Be sure to install Bypass Valve onto main control valve before beginning plumbing. Make provisions to bypass outside hydr
7TIME HOURSET2:00AM 1. Set time of day:1 2TIME MINUTESSET3CURRENT DAYSETMON4 PROGRAMMING PROCEDURES:NOTE: The manufacturer has preset the unit so that
STEP 4 – REGENERATION HOUR: The manufacturer has factory set 2:00 A.M. as the default. This is the hour of day for regeneration and can be reset by
39 If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN TODAY” will appear on the disp